Excellence in Manufacturing

 
DEC-specifications
 
DEC Pump Specifications
 
Drive Configuration V-Belt Direct    
  Agitator Chopper Suction Pipe
Recessed Impeller DEC Pumps
Metric (mm)
Imperial (inch)

(Toyo's standard settings) 96", 108", 120", 132", 144", 156" & 168" (settings greater than 168" will require intermediate bearings)

V-BELT DRIVE CONFIGURATION
BRG HSE max Motor size max D max S
3D 254 T 699 567
27.5 22.3
5E, 4E 326 T 870 738
34.3 29.1
6F, 7F 445 T 1115 1035
43.9 40.8
Pump Size DF L H X Y
51-80 80 203 200 398 221
3 8 7. 9 15. 7 8.7
61-50 50 203 200 366 263
2 8 7.9 14.4 10.4
61-100 100 203 200 479 240
4 8 7. 9 18.9 9.4
71/72-50 50 203 200 416 268
2 8 7.9 16.4 10.6
71/72-80 80 203 220 488 250
3 8 8.7 19.2 9.8
81/82-80 80 203 220 503 252
3 8 8.7 19.8 9.9
81/82-100 100 203 250 600 262
4 8 9.8 23.6 10.3
81/82-150 150 203 250 683 354
6 8 9.8 26.9 13.9
81/82-200 200 203 300 766 384
8 8 11.8 30.2 15.1
           
Agitator
ØR Ø1
381 28
15 1. 1
381 25
15 1
381 42
15 1. 7
381 25
15 1
381 28
15 1.1
508 35
20 1.4
508 50
20 2
525 65
20.7 2.6
600 65
23.6 2.6
 
Pump size Brg Hsg A B E F G ØJ K P W
51-80 to 71/72-80 3D, 4E, 5E 610 914 533 419 25.4 22 38.1 38.1 295
24 36 21 16.5 1 0.9 1.5 1.5 11.6
51-80 t o 71/72-80 6F, 7F 914 1219 838 572 25.4 22 38.1 38.1 381
36 48 33 22.5 1 0.9 1.5 1.5 15
81/82-80 t o 81/82-150  4E, 5E, 6F, 7F 914 1219 838 572 25.4 22 38.1 38.1 381
36 48 33 22.5 1 0.9 1.5 1.5 15
81/82-200 6F, 7F 914 1350 838 637 25.4 22 38.1 38.1 381
36 53 33 25.1 1 0.9 1.5 1.5 15

 
 
Toyo Pumps - Excellence in Manufacturing Toyo Pumps - Cross sectional Toyo Pumps - Specifications Toyo Pumps - Case Studies Toyo Pumps - Industries & applications
 
 
toyo pump
 
 
Toyo Pumps Toyo Parts Toyo Map
 
Toyo Pumps - Quote me a pump
Toyo Pumps - Tell us your thoughts Toyo Pumps - Download a Toyo Brochure Toyo Pumps - Toyo Modular Program
 
 
 
© Copyright 2008 Toyo Pumps North America Corp. All rights reserved. Click here to view Disclaimer and Copyright information